RDE0004 Platinum
RDE0005 Gold
RDE0006 Palladium
RDE0007 Silver
RDE0008 Glassy Carbon
RDE0009 Pyrolytic Graphite
Customer-Made Disk Electrodes. (Disk electrodes 11.3 mm diameter, 1 cm2 surfacearea. The material adjacent to the electrode surface is Teflon. The electrode bodyis Kel-F. 17.0 mm od shroud.) Order both the items listed below:
RDE0001 Disk Electrode Assembly (with a 430 SS sample)
RDE0002 Disk Installation Tools
Customer-Made Cylinder Electrodes. (Cylinder electrodes 12.0 mm diameter,12.4 mm height, 3.0 cm2 surface area. The material adj acent to the electrode surfaceis Teflon. The electrode body is Kel-F. 12.0 mm od shroud.) The Cylinder Electrode Assembly can be ordered either with or without a sample:
RDE0011 Cylinder Electrode Assembly and Tool (with a 430 SS sample)
RDE0012 Cylinder Electrode Assembly and Tool (without a sample)

RDE004.........................RDE001.........................RDE002.........................RDE0011
RDE004 Permanent Disk Electrode
RDE001 Disk Electrode Assembly
RDE002 Disk Installation Tools
RDE0011 Cylinder Electrode Assembly and Tool
If you wish to use the Model 636 as a simple rotating disk electrode, the electrodes listed above for the Model 616 (permanent disk, customer-made disks and customer-made cylinder) can be ordered for use with it. In addition, the following item also has to be ordered:

RDE0027 Disk Arbor and RDE0034 Ring Disk Arbor
RDE0029 Au Disk-Pt Ring
RDE0030 GC Disk-Pt Ring
RDE0031 Pt Disk-Pt Ring
RDE0032 GC Disk-GC Ring
In addition, the following item must be ordered with non-changeable disk electrodes:
RDE0034 Ring-Disk Arbor

RDE0033 Pt Ring ..............RDE0031 Ring-Disk
Removable Disk Assembly.........Electrode and Tools
K0060 Cell Bottom Kit
1601-0077-0 Cell Collar
1601-0009-7 Cell Bottom (glass, 5-50 ml)
K0066 Top Assembly (not used in rotating electrode applications; see Polarographic Accessories)
RDE0010 Top Assembly (Five holes. The center hole is 1.6 mm to accept the working electrode arbor, and the other four are 1.4 mm standard taper ports to accept reference and counter electrodes,purge tube, etc.)
RDE0019 Purge Tube
RDE0020 Reference Electrode Tube Assembly
RDE0021 Pt Counter Electrode Wire (6 in)
RDE0022 AgCI-KCI Filling Solution
RDE0023 Counter Electrode Bridge Tube
RDE0024 Reference Electrode Cap
RDE0025 Counter Electrode Cap and Screw
2811-0205-0 Counter Electrode Screw
RDE0018 Analytical Cell Kit Assembly Diagram
These items can also be ordered separately.
G0100 Vycor Frits, 4 mm (pkg of 5)
K0015 Polishing Kit
K0062 Cell Bottom Kit
1601-0077-09 Cell Collar
1601-0078-3 Cell Bottom (glass, 2-50 mi)
K0064 Jacketed Cell Bottom (a water jacketed version of the K0060 Cell Bottom suitable for connection to constant-temperature circulators)
K0085 Polarographic Cell Bottoms (pkg of 6)
RDE0026 Reference Bridge Tube